TM-1016

Product Price $ 200
count:

TM-1016-Require

TM-1016

TM-1016  AC-HVAC Clamp Phase

 
This apparatus conforms to safety standard EN 61010
 

Application

It can be used for CURRENT, VOLTAGE and FREQUENCY measurements on installations of surge voltage category III up to 600 V, voltage between Phase and Earth (fixed installations) and for current measures up to 400A.
 
 
 
 
 

Features

The apparatus can perform the following measurements:
  • AC current (IAC).
  • AC uA current(I AC).
  • DC uA current.(I DC).
  • AC voltage (VAC).
  • DC voltage (VDC).
  • DC current (IDC).
  • Resistance.
  • Continuity Test.
  • Capacitance.
  • Temperature 
 
 

Specifications

  • Display:3 ¾ LCD with maximum reading 3999 units plus decimal point signs plus backlight
  • Sample rate:2 times/sec.
  • Jaws opening:30mm
  • Max conductor size:30mm
  • Dimension: 205mm(L)x64mm(W)x39mm(H).
  • Weight:about 280g. (Including battery)
CHARACTERISTICS SPECIFICATIONS(23℃±5℃, with RH< 75%RH )
DC µA (Auto/Manual)
Range
Resolution
Accuracy
Burden Voltage
Overload Protection
400µA
0.1µA
±(1.0%+2)
500uV/uA
0.2A/250V Fuse
4000µA
1µA

AC µA (Auto/Manual)
Range
Resolution
Accuracy
50Hz~60 Hz
Burden Voltage
Overload Protection
400µA
0.1µA
±(1.2%+3)
500µV/µA
0.2A/250V Fuse
4000µA
1µA

ACA (Auto/Manual)
Range
Resolution
Accuracy
50Hz~60 Hz
Overload Protection
40A
0.01A
±(2.0%+10)
600A rms (60 second)
400A
0.1A
±(1.5%+10)

DCV (Auto/Manual)
Range
Resolution
Accuracy
Input Impedance
Overload Protection
4V
1mV
±(0.8%+2)
11MΩ
DC/AC660V rms
40V
10mV
10MΩ
400V
100mV
600V
1V
±(1.0%+2)

ACV (Auto/Manual)
Range
Resolution
Accuracy 50Hz~500 Hz
Input Impedance
Overload Protection
4V
1mV
±(1.0%+3)
11MΩ
DC/AC660V rms
40V
10mV
10MΩ
400V
100mV
600V
1V
±(1.2%+3)

Resistance (Auto/Manual)
Range
Resolution
Accuracy
Max. Open Voltage
Overload Protection
400Ω
0.1Ω
±(0.8%+5)
about -1.5VDC
DC/AC600V rms
(60Second)
4KΩ
1Ω
±(0.8%+2)
About-0.45VDC
40KΩ
10Ω
400KΩ
100Ω
4MΩ
1KΩ
40MΩ
10KΩ
±(3%+2)

Continuity Test
Range
Buzzer
Max. Open Voltage
Overload Protection
below 25
About-1.5VDC
600V rms

Capacitance (Auto/Manual)
Range
Resolution
Accuracy
Overload Protection
4nF
1pF
±(3%+10)
DC/AC600V rms
(60Second)
40nF
10pF
400nF
100PF
4µF
1nF
40µF
10nF
400µF
100nF
4mF
1µF
±(5%+10)

Temperature:optional temp.probe:K(CA) type.
Range
Resolution
Accuracy
°C
1°C
-50°C~ 0°C±(1.8%+2°C) 
0°C~ 500°C±(1.0%+2°C) 
500°C~ 1200°C±(1.8%+2°C)
°F
1°F
-58°F~ 32°F±(1.8%+3°F) 
32°F~ 932°F±(1.0%+3°F) 
932°F~ 1999°F±(1.8%+3°F)
The tolerance of temp. Probe excluded.
Max.input voltage for thermocouple:DC60V,AC24V

 

 

Accessories

 

Download

file name
Version
Format
Download
EN. User’s Manual
HB2TM1016UL2_UL
PDF

 

Cart

Login