TM-16E  AC Clamp Meter

 
 
 

Application

  • Measuring voltage over 20V as it may cause human body electricity conduction.
  • Measure AC power. 
  • Operating Environment: Indoor use. This instrument has been designed for using in an environment of pollution degree 2.
  • Operation Altitude: up to 2000m.
  • Operating Temperature & Humidity: 5℃ ~ 40℃,below 80%RH.
  • Storage Temperature & Humidity: -10℃ ~ 60℃, below 70%RH.
  • Fingers should hold under the protection guard of test probe.
  • Category: CATⅡ 600V for body. CATⅢ 600V for clamp.
 
 
 
 

Features

AC Current (ACA) measurement
  • Make sure that all the test leads are disconnected from the meter’s terminal for current measurement.
AC Voltage (ACV) measurement
  • Maxim input for DCV or ACV is 600V.
Resistance measurements
  • Before taking any in circuit resistance measurement, remove power from the circuit being tested and discharge all the capacitors. If a reading is over range, the message “OL” will be displayed.

 

 
 

Specifications

  • Display: 3½digits LCD with maximum reading 1999, Plus decimal point, unit symbol indication.
  • Overload Indication: LCD will show a “1” in the left highest position.
  • Low Battery Indication: Replace battery as LCD display “ ”.
  • Sampling Rate: 2 times per second for digital display.
  • Jaws opening:30mm
  • Max conductor size:30mm
  • Dimension: 195mm(L)x64mm(W)x30mm(H).
  • Weight:about 240g. (Including battery)
Electrical Specifications
ACA (Auto)
Range
Resolution
Accuracy
50Hz~60 Hz
Overload
Protection
200A
0.01A
±(2.0%+5)
600A rms
(60 second)
600A
0.1A

ACV (Auto)
Range
Resolution
Accuracy
50Hz~500Hz
Overload Protection
200A
0.1V
±(1.5%+5)
660V rms
600A
1V

ACV Input Impedance 1MΩ

Continuity
Range
Buzzer
Max. Open
Voltage
Overload
Protection
below 100
-1.6VDC
500V rms

Resistance
Range
Buzzer
Accuracy
Max. Open Voltage
Overload Protection
200
0.1Ω
±(1.9%+3)
-1.6VDC
500V rms

 

 